Home  |  Sitemap  |  Contact us
Home > Engineer guide > Cable group
Cable Number  SS402 047TP RG-405/U 085 TP RG-402/U 141 TP
M17 Number  M17/130
- RG402
M17/151
-00001
M17/133
- RG405
M17/133
-00001
M17/130
- RG402
M17/130
-00001
 DIMENSIONS(mm)
Center Conductor  0.93 0.29 0.51 0.51 0.92 0.92
Dielectric  2.97 0.94 1.68 1.68 2.98 2.98
Outer Conductor  3.58 1.19 2.20 2.20 3.58 3.58
Jacket  4.14 None None None None None
 MATERIAL
Center Conductor  Silver-Coated
Copper Clab
Steel
Silver-Coated
Copper Clab
Steel
Silver-Coated
Copper Clab
Steel
Silver-Coated
Copper Clab
Steel
Silver-Coated
Copper Clab
Steel
Silver-Coated
Copper Clab
Steel
Dielectric  PTFE Type F-1 PTFE Type F-1 PTFE Type F-1 PTFE Type F-1 PTFE Type F-1 PTFE Type F-1
Outer Conductor  Silver-Coated
Copper &
Copper Strip
Tin Plated
Copper-Tube
Copper Tin
Composite
Shield
Tin Plated
Copper-Tube
Copper Tin
Composite
Shield
Tin Plated
Copper-Tube
Jacket  FEP None None None None None
 CABLE
 CONSTRUCTION
Center Conductor  Solid Solid Solid Solid Solid Solid
Dielectric  Solid Solid Solid Solid Solid Solid
Outer Conductor  Helical
Wrap/Braid
Solid Wrap & Tin
 Braid
Solid Wrap & Tin
 Braid
Solid
 WEIGHT
 (Max. Kg/100 m)
5.3 0.57 1.8 2.0 4.5 4.67
 TEMPERATURE
 RATINGS
(Min. to Max., ¡É)  -65 to +200 -40 to +150 -40 to +200 -40 to +125 -40 to +200 -40 to +125
 FREQUENCY
 (Max. §×)
18 20 20 20 20 20
 ATTENUATION
 (dB/100 ft)
Frequency(§Ö) 400  7.2 23 13.5 13 7.1 7.8
1000  13 34.2 22 22 12 11.3
3000  22 55 37 35 21 21
5000  30 78.8 52 50 29 28
10000  45 113.8 80 80 45 42
 POWER HANDLING
 (Watts)
Frequency(§Ö) 400  720 69 220 220 483 483
1000  440 47.7 130 130 336 336
3000  260 30.5 74 74 200 200
5000  170 20.7 54 54 94.6 94.6
10000  110 9.9 35 35 62.7 62.7
 VSWR (Max)
Frequency(§Ö) 500  1.15 1.08 1.08 1.08 1.07 1.07
1000  1.15 1.17 1.09 1.09 1.08 1.08
3000  1.25 1.19 1.13  1.12 1.12 1.12
10000  1.25 1.29 1.22 1.22 1.17 1.17
 VOLTAGE RATING
 (Volts RMS)
Continuous Working 
Voltage (Max) 
1900 1000 1500 1500 1900 1900
Voltage Withstanding 
(+10%-0%) 
- 2000 5000 5000 5000 5000
Corona Extinction 
Voltage (Min) 
- 1000 1500 1500 1900 1900
 CHARACTERISTIC
Impedance(Ohms)  50 50 50 50 50 50
 MINIMUM INSIDE
 BEND
(Radius, In.)  0.8 0.05 - 0.05 - 0.075
 VELOCITY OF
 PROPAGATION
(Nom., %)  70 69.5 69.5 69.5 69.5 69.5
 SHIELDING
 EFFICENCY, dB/ft
>100 >100 >100 >100 >100 >100